Ventilator 100

Trilogy is a device that is designed to provide ventilator support for a wide variety of patient conditions. The Trilogy Ventilator by Philips Respironics is light, versatile, and easy to use. This machine offers portable volume and pressure support, with proven BiPAP technology. Therapy can be utilized either invasively or noninvasively. Invasive ventilator uses an endotracheal tube or a tracheostomy tube. Noninvasive administers ventilation support through a mask. This versatility means that the Trilogy Ventilator can be utilized by patients suffering from a wide array of different health conditions.

Instructions

Demonstration Videos

For privacy reasons YouTube needs your permission to be loaded.
For privacy reasons YouTube needs your permission to be loaded.
For privacy reasons YouTube needs your permission to be loaded.

SPECIFICATIONS

Dimensions and weight
Dimensions
  • 16.68 cm L x 28.45 cm W x 23.52 cm H (6.6″ L x 11.2″ W x 9.3″ H)
Weight
  • 5 kg (11 lb)
Controls
Circuit types
  • Active with PAP; passive
Ventilation types
  • Pressure and Volume
Volume modes
  • AC; SIMV (w/PS); CV; AC-MPV
Pressure modes
  • CPAP; S; S/T; T; PC-SIMV (w/PS);PC-MVP; AVAPS-AE
Pressure
  • 4 to 50 cm H₂O
IPAP
  • 4 to 50 cm H₂O
PEEP/EPAP for active circuits
  • 0 to 25 cm H₂O
PEEP/EPAP for passive circuits
  • 4 to 50 cm H₂O
CPAP for passive circuits
  • 4 to 20 cm H₂O
PEEP for active circuits
  • 0 to 25 cm H₂O
PEEP for passive circuits
  • 4 to 25 cm H₂O
PEEP for passive circuits
  • 4 to 20 cm H₂O
Pressure support differential
  • 0 to 40 cm H₂O
Alarms
Apnea rate
  • Off; 10 to 60 sec
Circuit disconnect
  • Off; 5 to 60 sec
High tidal volume
  • Off; 50 to 2000 ml
Low tidal volume
  • Off; 40 to 2000 ml
High minute ventilation
  • Off; 1.0 to 99 l/min
Low minute ventilations
  • Off; 0.2 to 99 l/min
High respiratory rate
  • Off; 4 to 80 BPM
Low respiratory rate
  • Off; 4 to 80 BPM
Measured patient parameters
Respiratory rate
  • 0 to 80 BPM
Minute ventilation
  • 0 to 99 l/min
Vte/Vti
  • 0 to 2000 ml
Leak rate
  • 0 to 2000 l/min
Peak inspiratory flow
  • 0 to 2000 l/min
Peak inspiratory pressure
  • 0 to 99 cm H₂O
Mean airway pressure
  • 0 to 99 cm H₂O
% Patient triggered breaths
  • 0 to 100 %
I:E ratio
  • 9.9:1 to 1:9.9
Controls
Tidal volume
  • 50 to 2000 ml
Breath rate
  • 0 to 60 for AC mode; 1 to 60 BPM for all other modes
Inspiratory time
  • 0.3 to 5.0 sec
Rise time
  • 1 to 6
Ramp start pressure
  • 0 to 25 cm H2O for active circuits; 4 to 25 cm H2O for passive circuits; 4 to 19 cm H2O in CPAP cm H₂O
Ramp length
  • Off; 5 to 45 min
Flex
  • Off; 1 to 3
Flow trigger sensitivity
  • 1 to 9 l/min
Flow cycle
  • 10 to 90 %
Apnea rate
  • 4 to 60 BPM
Apnea rate
  • Off; 10 to 60 sec

USER MANUAL

Trilogy-100-Ventilator-Information-and-User-Guide

Trilogy-Clinical-Manual

FREQUENTLY ASKED QUESTIONS

Helpful Hints

Features

Keeping care teams in the know

Trilogy is now connected to Care Orchestrator, our HIPAA-compliant cloud-based patient management system. With the ability to transmit data wirelessly and remotely, Connected Trilogy helps providers deliver quality respiratory care, gain efficiencies, potentially avoid unnecessary home visits, improve care coordination, streamline workflow and prioritize patient need.

Continuous respiratory support for added freedom and mobility

Trilogy provides respiratory support to meet your prescribed needs, up to 24 hours a day. Trilogy is portable with internal, hot-swappable detachable, and external batteries to provide greater freedom and mobility with continuous ventilation. The easy-to-use carry bag is wheelchair-mountable and designed so the screen is always visible.

Easy to use and adaptable for your patients’ changing needs

Trilogy is designed with easy-to-read and navigate screens, multiple Rx settings and on-screen waveforms to help optimize treatment. Trilogy’s pressure- and volume-control features allow you to provide more types of therapy with one device. The ability to use multiple modes for patients who require varying levels of ventilation, allows greater flexibility in care.

Adapting with every breath

AVAPS-AE–an auto-titration mode of non-invasive ventilation with multiple algorithms that work simultaneously–meets the changing needs of your patients. AVAPS automatically adjusts to breathing, while Auto EPAP proactively adjusts to the lowest effective pressure for peak comfort. Auto Backup delays a machine breath until the patient has exhaled to reduce air trapping.

Delivering on-demand ventilation

With no inspiratory effort required to trigger a breath, our unique ‘kiss’ trigger detects when a patient engages and disengages from the mouthpiece to deliver on-demand ventilation with the security of patient alarms.

When sensitivity is needed most

This adaptive algorithm automatically adjusts the triggering and cycling of the ventilator, while compensating for leaks. Digital Auto-Trak’s capability contributes to the patient’s synchrony and comfort, without requiring manual adjustments. The Sensitive Auto-Trak setting provides an enhanced triggering response for patients with minimal respiratory effort.

The support and training you need

The innovative technology of the Trilogy family sets it apart from the rest. The support, service and upkeep behind all of it keeps it there, including 24/7 clinical support, educational training resources for both you and your patients and extended warranties and maintenance plans.

Enhance patient mobility and care with Trilogy accessories

From power options and circuit adapters, to reporting software and alarms, Trilogy’s array of accessories helps give patients and families more freedom and mobility while maintaining effective treatment.

RELATED ITEMS