One REMStar 60 Series Auto Instructions
The PR System One REMStar 60 Series Auto CPAP Machine is an auto-adjusting CPAP machine that covers all the bases using Flex Technology to deliver the minimal pressure needed to maintain effective therapy with exhalation relief. Add the Optional System One Humidity Control and Heated Tube to extend maximum therapy comfort and relieve many therapy side effects.
Demonstration Videos
SPECIFICATIONS
This Product Includes…
- System One REMStar 60 Series Auto CPAP
- System One REMStar 60 Series Power Supply and Cord
- Hose
- Carrying Case
- SD Memory Card
- Reusable Foam Filter (2)
- Patient Manual
- Clinical Quick Setup Guide
Product Specifications
Pressure Range: 4-20 cm H2O (.5 increments)
Ramp Time: 0 to 45 min. (5-min. increments)
Starting Ramp Pressure: 4 to set CPAP pressure; user adjustable
Dimensions – Machine Alone: 7 in L x 5.5 in W x 4 in H (18 cm L x 14 cm W x 10 cm H)
Dimensions – Machine with Heated Tube Humidifier: 10.75 in L x 6.5 in W x 4 in H (27 cm L x 16.5 cm W x 10 cm H)
Weight – Machine Alone: 3 lbs / 1.36kg
Dimensions of 60 Watt Power Supply (For Use Without Heated Tube) – Not Including Cord or Plug:4.75 in x 2.75 in x 1.75 in
Weight of 60 Watt Power Supply – Not Including Cord: 14.72 oz (0.92 lbs)
Dimensions of 80 Watt Power Supply (For Use With Heated Tube) – Not Including Cord or Plug: 6 in x 2.75 in x 1.75 in
Weight of 80 Watt Power Supply (For Use With Heated Tube) – Not Including Cord: 1 lb 3.04 oz
AC Power Consumption (with 60 W power supply): 100 – 240 VAC, 50/60 Hz, 2.1 A max.
AC Power Consumption (with 80 W power supply): 100 – 240 VAC, 50/60 Hz, 2.0 A max.
DC Power Consumption: 12 VDC, 6.67 A
Altitude Compensation: Automatic – Maximum Height 7500 feet.
Sound Level : Less than 30 dBA
22mm Performance Tube Length: 72 inches
Optional Heated Hose Length: 72 inches
Filters: Pollen (Foam) and optional ultra-fine (Disposable)
Device Set-Up: On Screen Display and Control Dial/Knob
Data Storage Capacity:
- Display: Compliance, AHI, Leak, Pressure 7-Day and 30-Day averages
- SD Card: >1 year (daily details with flow waveforms)
- On-board: up to 6 months
Compliance Meter: Breathing detection
Electrical Requirements: 100 – 240 VAC, 50/60 Hz, 12volt DC
European Voltage Usage: Yes, outlet adapters required
Max Exposure Heat for Machine: Machine should not be exposed to heat greater than 140 degrees Fahrenheit
Sound Level – Mask Leak Alert: 35 dB, +/- 2 dB
Optional Heated Tubing Specifications
Maximum Recommended Pressure: 25 cm H20
Inner Diameter: 15 mm (0.6 in.)
Length: 1.83 m (6 ft)
Heated Tubing Temperature Range: 16º to 32º C (60º to 89º)
Heated Tubing Temperature Cut-out: ? 41º C (? 106º F)
Material: Flexible plastic and electrical components
Required Settings: This machine does not have required settings.
Unless directed otherwise, CPAP.com will leave this machine at its default settings of:
- C-flex: 2
- Auto On: On
- Auto Off: Off
- Pressure Setting: 4-20 cm H2O
USER MANUAL
FREQUENTLY ASKED QUESTIONS
Helpful Hints
Product Features
The PR System One REMStar 60 Series Auto CPAP Machine is an auto-adjusting CPAP machine that covers all the bases using Flex Technology to deliver the minimal pressure needed to maintain effective therapy with exhalation relief. Add the Optional System One Humidity Control and Heated Tube to extend maximum therapy comfort and relieve many therapy side effects.
Features Include:
- System One 60 Series Heated Tube Humidifier with Heated Tube – Optional
- Modern Design
- Flex Technology
- System One Resistance Control
- On Screen Data
- Opti-Start
Optional System One Humidity Control and Integrated Heated Tube
Philips Respironics 60 Series machines can be used with the optional Heated Tube and System One Humidity System. Together they maximize comfort while managing rainout and potential water damage. The level of relative humidity delivered to the mask is adjusted by analyzing the ambient room temperature and machine airflow. The optional slim 15mm Heated Tube maintains the desired temperature evenly from the machine to the mask.
When the optional 60 Series Heated Humidifier and Heated Tube are added to the 60 Series Auto CPAP machine use the on-screen menu to select one of three available levels of relative humidity (70, 80 or 90 percent). Next, adjust the control dial to choose from 5 levels of heated tube temperature, ranging from 4 to 16 degrees above room temperature. The optimum humidification level at the mask is easy to maintain when using the PR System One REMStar 60 Series Auto CPAP with humidification assembly.
The System One 60 Series Humidifier has a redesigned chamber resulting in an increase in surface area and greater humidification output. It has been reformatted to work with the Heated Tube which easily snaps on and off the humidifier port.
The System One Dry Box technology stands alone in reducing the chance of water damage to the CPAP. Unique design features prevent water from exiting the chamber and entering the machine. The center air outlet port uses a one way valve. This location on the chamber helps to minimize total water displacement. If water were to escape the chamber it is trapped within the reservoir of the Dry Box.
Modern Design
The PR System One REMStar 60 Series Auto CPAP Machine sports an updated look with a rich charcoal color and metallic silver as accents on the control and side panels. The control dial has been redesigned to make it easier to grasp.
Flex Family Technology
Traditional CPAP therapy is enhanced with easy breathing Flex Technology. People new to CPAP therapy find adapting to treatment easier when the airflow pressure is slightly reduced upon exhalation. The 60 Series Auto CPAP offers C-Flex, C-Flex Plus and A-Flex modes.
C-Flex delivers comfortable sleep therapy through pressure relief at exhalation. Pressure is lowered based on a breath-per-breath analysis and provides up to 3 levels of relief based on the user’s expiratory flow.
C-Flex Plus softens the breathing cycle between inhalation and exhalation based on expiratory flow. It minimizes the transition between pressures and provides greater comfort when in the fixed-pressure CPAP mode.
The A-Flex comfort feature is built on top of the REMstar Auto algorithm which provides the lowest pressure needed to keep the airway open during sleep. A-Flex adjusts to deliver pressure as needed to eliminate breathing events without raising it too high.
System One Resistance Control
In order to deliver optimal pressure Respironics developed a numbering system to note the resistance characteristics of each mask. Using the Resistance Control number, the machine compensates for the mask being used to provide a consistent and reliable pressure.
Sleep Data
Sleep data is available on the display screen of the System One 60 Series Auto CPAP machine. See the Apnea/Hypopnea Index, leak rate as well as the 7 and 30 day average pressure readings. Data is stored in both an on-board memory and a generic SD memory card.
Philips Respironics offers the updated version of their popular OPTIONAL software: EncoreViewer 2.1 Software for Respironics Machines. It is compatible with 64 bit systems and offers both viewing and printing of sleep therapy data.
Opti-Start Comfort Technology
Opti-Start technology is designed to provide the optimum therapy starting pressure. When Opti-Start is set to “on”, after 30 hours, the machine begins therapy at the average pressure used. As therapy continues, the machine automatically adjusts the delivered pressure on a breath by breath basis as usual. If Opti-Start is turned on, the ramp feature will NOT function.
Important Compatibility Note
The PR System One REMStar 60 Series Auto CPAP can only be used with the optional 60 Series Heated Humidifier. The optional Heated Tube CANNOT BE used with any other PR System One machines and humidifiers. The external power supply used by this system IS NOT compatible with other units in the Philips Respironics line of products.
The REMStar 60 Series Auto CPAP is not compatible with earlier versions of the PR System One Heated Humidifier.
Further the Heated Humidifier and Heated Tube that interface with the PR System One REMStar 60 Series Auto CPAP with Heated Humidifier and Heated Tube is not compatible with the PR System One REMstar Auto CPAP Machine with A-Flex or any other machines in the PR System One product line.
The 60 Series machines and humidifiers cannot physically be attached to earlier versions in the Philips Respironics line of products.
See the Important Tips tab on this product page for further information.
RELATED ITEMS
Remote Patient Monitors
Remote Patient Monitoring Devices Often abbreviated as Read more...
How To Use A Disposable Lancet Instructions
How do you use a lancet step by Read more...
AED, Automated External Defibrillator Instructions
Instructions for AED, Automated External Defibrillators: Video demonstrations Read more...
Subcutaneous Injection Instructions
Instructions for Subcutaneous Injections: Video demonstrations User manuals Read more...
Enteral Feeding Management Instructions
Instructions for Enteral Feeding Management: Video demonstrations User Read more...
Nutrition TPN Management Instructions
Instructions for Nutrition TPN Management: Video demonstrations User Read more...
Catheter & Central Line Management Instructions
Instructions for Catheter Management: Video demonstrations User manuals Read more...
IV & Syringe Pump Instructions
Instructions for IV & Syringe Pumps: Video demonstrations Read more...
Medication Preparation Instructions
Instructions for Medication Preparation: Video demonstrations User manuals Read more...
Walkers and Rollator Instructions
Instructions for Walkers and Rollator: Video demonstrations User Read more...
Bath Item Instructions
Instructions for Bath Items: Video demonstrations User manuals Read more...
Homecare Bed Instructions
Instructions for Homecare Beds: Video demonstrations User manuals Read more...
Support Surface Instructions
Instructions for Scooters: Video demonstrations User manuals & Read more...
Scooter Instructions
Instructions for Scooters: Video demonstrations User manuals & Read more...
Wheel Chair Instructions
Instructions for Wheel Chairs: Video demonstrations User manuals Read more...
FreeStyle Freedom Lite Blood Glucose Monitoring System
MedExplains Audio, Video and Text Instructions for Homecare Read more...
MedExplains
Audio, Video and Text Instructions for Homecare Patients Read more...
Telehealth
Telehealth - Telemedicine and Remote Patient Monitoring Read more...
AliveCor Kardia RPM
ALIVECOR Kardia - ECG RPM KardiaCare’s Read more...