These beds deliver new and innovative features that further meet patients needs. The G-Series bed complies with the international standard for hospital bed safety and essential performance, IEC 60601-2-52. With the G-Series bed, you will have the peace of mind that your bed frame, mattress and rails have passed stringent tests to ensure the highest standard for patient safety in the homecare and long term care environments. This video is for instructional purposes only and does not replace the use of owner’s manual. Patients need to consult with their physician or other health care provider prior to using these products. Be sure to check the owner’s manual for a list of approved accessories.

Demonstration Videos

For privacy reasons YouTube needs your permission to be loaded.
I Accept
For privacy reasons YouTube needs your permission to be loaded.
I Accept
For privacy reasons YouTube needs your permission to be loaded.
I Accept

Setting up Invacare’s G-Series beds involves several steps to ensure proper assembly and safe operation.

Here’s a step-by-step guide:

Materials Needed

  • Invacare G-Series bed frame and components
  • Hand control pendant
  • Head and footboards
  • Mattress
  • Power supply
  • Tools as specified in the user manual (e.g., screwdriver, wrench)

Procedure

  1. Unpacking and Inspection
    • Carefully unpack all components and check for any damage or missing parts.
    • Ensure you have all the components listed in the assembly instructions.
  2. Assemble the Bed Frame
    • Place the bed frame in the desired location. Ensure there is enough space around the bed for assembly and operation.
    • Attach the head and footboards to the frame. Typically, this involves aligning the mounting brackets on the boards with the corresponding slots on the frame and securing them with the provided bolts or screws.
  3. Install the Motor and Hand Control
    • Locate the motor and control system. The motor assembly usually attaches to the underside of the bed frame.
    • Follow the manufacturer’s instructions to secure the motor to the frame. This may involve aligning the motor with pre-drilled holes and securing it with bolts.
    • Connect the hand control pendant to the motor assembly. Ensure the connection is secure.
  4. Attach the Bed Deck
    • If the bed deck (where the mattress sits) comes in separate sections, assemble them according to the instructions.
    • Secure the bed deck to the frame using the provided hardware. Make sure the deck is level and stable.
  5. Install Side Rails (if included)
    • Position the side rails according to the instructions. Typically, they attach to the sides of the bed frame.
    • Secure the side rails with the provided hardware. Ensure they can move up and down smoothly and lock in place.
  6. Connect the Power Supply
    • Plug the power supply into the motor assembly.
    • Ensure the power cord is safely routed and not a tripping hazard.
    • Plug the power supply into a grounded electrical outlet.
  7. Test the Bed Functions
    • Use the hand control pendant to test all bed functions, including raising and lowering the head, foot, and overall bed height.
    • Ensure all movements are smooth and that the bed responds correctly to the hand control commands.
  8. Place the Mattress on the Bed
    • Once the frame is fully assembled and tested, place the mattress on the bed deck.
    • Ensure the mattress is properly positioned and does not obstruct any moving parts.
  9. Final Inspection
    • Double-check all connections and hardware to ensure everything is secure.
    • Verify that the bed operates smoothly and safely.

Tips

  • Refer to the user manual provided by Invacare for specific instructions and diagrams.
  • If you encounter any difficulties or have questions about the setup, contact Invacare customer support for assistance.
  • Ensure that the bed is on a flat, stable surface to prevent any instability.

Setting up Invacare’s G-Series beds should be straightforward if you follow these steps carefully. If you need more detailed guidance, consulting the user manual or seeking professional assistance is recommended.

 

Guidelines, Specifications & User Manuals

Helpful Information

 Invacare’s G-Series beds deliver new and innovative features that further meet patients’ needs. The G-Series bed complies with the international standard for hospital bed safety and essential performance, IEC 60601-2-52. With the G-Series bed, you will have the peace of mind that your bed frame, mattress and rails have passed stringent tests to ensure the highest standard for patient safety in the homecare and long-term care environments.

Invacare beds, mattresses and rails, excluding therapeutic support surfaces and bariatric beds, when used as a system and sold new after August 1, 2007, meet the voluntary FDA Guidelines for bed rail entrapment. Visit www.invacare.com/bedsafety for additional safety and entrapment information.

View the Bed Rail Entrapment Risk Notification Guide

Supportive Sleep Surface – The slat deck provides a comfortable sleep surface for patients, reduces wear and tear on the mattress and is simple to clean, allowing for improved infection control.

Interchangeable Bed Ends – Extra extensive travel range. Easy to clean and impact resistant.

Ergonomic Bed Sections – Ergonomically designed head and foot sections with elongated head section for increased patient comfort.

IP66 Rating – Water resistant connections to prevent fluid ingress. Crank Through electronics – Allows all motors to be operated manually in the event of a power outage.

Coming Soon! New Head Section Articulating Half Rail – Durable, powder-coated clamp on rail, no tools required. Rails articulate with the head section of the bed.

Newly Designed Backlit Hand Pendant – The new backlit pendant is ergonomically designed with an extended heavy duty strain relief for increased flexibility. Connects on either side of the bed for patient’s ease of use. Backlit pendant and raised buttons offers easy operation in low light situations.

Dimensions:
36″ (W) x 88″ (L)

Range:
Bed Deck Travel Range: 15″ – 32″

Product Weight Capacity:
450 lb.
Patient Weight Capacity: 350 lb.

Electrical:
IP66

Code Approval:
Regulatory Standards: IEC 60601-2-52, IEC60601-1-11, ANSI/AAMI 60601, 3rd ed., IP66

Warranty:
2 year warranty – Mechanical and Electrical
5 year warranty – Welds

NOTE: For more detail please refer to the full specifications brochure link above, or call Customer Service at (800) 333-6900. All specifications, prices, and product configurations are subject to change without notification. Accessories and seating products shown in the photographs are not necessarily included in the base price of wheelchair. Please refer to current price lists located at www.invacare.com.

* MSRP – Manufacturer’s Suggested Retail Price does not include optional equipment and accessories that may be available for this product.

** This information is not intended to be, nor should it be considered billing or legal advice. Providers are responsible for determining the appropriate billing codes when submitting claims to the Medicare Program and should consult an attorney or other advisor to discuss specific situations in further detail.

Related Devices