The discreet FreeStyle Lite blood glucose monitoring system gives you accurate results from a tiny blood sample. Now it’s easy to manage your diabetes on-the-go. The small, discreet FreeStyle Lite system offers big advantages. There’s no coding needed and this meter requires a small blood sample size. Plus, it has a convenient backlight and test strip port light, so you can test anytime. Small and portable design. Backlight display and test strip port light. No coding, means one less step. Small sample size, only 0.3 L. Fast, 5-second average test time. FreeStyle Lite blood glucose test strips are intended to be used with FreeStyle Lite and FreeStyle Freedom Lite meters only.
Instructions
Demonstration Videos
USER MANUAL
SPECIFICATIONS
Specifications
Assay method Coulometric electrochemical sensor
Automatic shutoff 2 minutes of inactivity
Battery life 500 tests
Calibration Plasma equivalent
Hematocrit 15% to 65%
Measurement units mg/dL
Meter storage
temperature – 4° to 140° F (–20° to 60° C)
Memory 400 blood glucose and control solution tests with date and time
Operating relative
humidity 5% to 90% (non-condensing)
English
41
Specifications (continued)
Operating
temperature 40° to 104° F (4° to 40° C)
Power source One CR 2032, 3V lithium battery, replaceable
Result range 20 to 500 mg/dL
Sample Fresh capillary and venous whole blood samples
Sample size 0.3 microliter (300 nanoliters)
Size 1.57 in (w) x 2.9 in (l) x 0.65 in (d) 4.0 cm (w) x 7.4 cm (l) x 1.7 cm (d)
Weight 1.0 to 1.1 oz. (28.3 to 31.2 g) including battery
Meter cleaning and
disinfection
The meter has a use life of 5 years, which is 522 cleaning and 522
disinfection cycles (2 cycles per week for 5 years).
Lancing device cleaning
and disinfection
The lancing device has a use life of 2 years, which is 210 cleaning
and 210 disinfection cycles (2 cycles per week for 2 years).
English
Contact Customer Care Toll Free at 1-888-522-5226 www.MyFreeStyle.com
FREQUENTLY ASKED QUESTIONS
Helpful Hints
Test strips designed for
EASE OF USE AND ACCURACY
The FreeStyle Lite meter is compatible with FreeStyle Lite test strips. These test strips feature:
- Tiny sample size – only 0.3 µL
- Patented ZipWik tabs that make application quick and easy
- Up to 60 seconds to re-apply blood means FEWER wasted test strips
- No coding means one less step
- Automatic, more affordable5 co-pay6 for test strips every month with the FreeStyle Promise Program4
Test strips sold separately.
Frequently Asked Questions
Which test strips should I use with the FreeStyle Lite meter?
The FreeStyle Lite meter is intended to be used with FreeStyle Lite blood glucose test strips only.
What is included in the FreeStyle Lite retail system kit?
1 FreeStyle Lite meter
1 Lancing device
10 Lancets
1 Carrying case
Owner’s guide
How do I set the time and date on the FreeStyle Lite meter?
Watch the Quick Start video.
Can the FreeStyle Lite system be used to test on alternate sites?
Yes, you can test on upper arms and palms. However, when testing for hypoglycemia or if you have hypoglycemia unawareness, we recommend testing on the finger only.
Where can I buy FreeStyle products?
Find FreeStyle meters and test strips at a store near you.
Do I need to register the meter and how do I get warranty support?
You no longer need to register your meter for warranty coverage. You’re automatically eligible for the limited warranty. Just retain your proof of purchase. If you’re experiencing problems with your meter, or if you want support in the future, please call Customer Support Monday through Friday 8am to 8pm Eastern Time at (888) 522-5226.
Freestyle-lite Glucose Monitors
Setting up and maintaining the FreeStyle Lite blood glucose monitoring system involves several steps to ensure accurate and reliable blood glucose readings. Here is a detailed guide:
Setting Up the FreeStyle Lite Blood Glucose Monitoring System
- Unpack the System:
- Open the package and ensure all components are present: FreeStyle Lite meter, lancing device, lancets, test strips, control solution, carrying case, and user manual.
- Insert the Battery:
- Locate the battery compartment at the back of the meter.
- Open the compartment, insert the battery provided, and close the compartment.
- Set the Date and Time:
- Turn on the meter by pressing the power button.
- Follow the on-screen prompts to set the date and time. This is crucial for accurate record-keeping.
- Prepare the Lancing Device:
- Remove the cap from the lancing device.
- Insert a new lancet into the holder and twist off the protective cap from the lancet.
- Replace the lancing device cap and adjust the depth setting according to your comfort level.
- Prepare the Test Strip:
- Take a test strip from the vial and insert it into the meter. The meter will turn on automatically.
Performing a Blood Glucose Test
- Wash and Dry Your Hands:
- Clean your hands with soap and water, then dry them thoroughly.
- Obtain a Blood Sample:
- Use the lancing device to prick the side of your fingertip.
- Gently squeeze your finger to obtain a small drop of blood.
- Apply Blood to the Test Strip:
- Touch the edge of the test strip to the drop of blood. The meter will automatically draw in the blood and begin the test.
- Read the Results:
- Wait for a few seconds while the meter analyzes the blood sample.
- Your blood glucose level will be displayed on the screen.
- Log the Results:
- Record the results in your logbook or use the meter’s memory to track your readings.
Maintaining the FreeStyle Lite Blood Glucose Monitoring System
- Regular Cleaning:
- Wipe the meter with a soft, damp cloth regularly.
- Do not immerse the meter in water or use harsh cleaning agents.
- Store Properly:
- Keep the meter and test strips in the carrying case.
- Store the system in a cool, dry place away from direct sunlight and extreme temperatures.
- Check Expiration Dates:
- Ensure test strips and control solutions are not expired. Expired materials can give inaccurate results.
- Perform Control Tests:
- Use the control solution to test the meter periodically to ensure it is working correctly. Follow the instructions in the user manual for this procedure.
- Replace Lancets:
- Use a new lancet for each test to maintain hygiene and ensure comfort.
- Battery Replacement:
- Replace the battery when the low battery symbol appears on the screen. Follow the instructions for battery replacement in the user manual.
Troubleshooting
- Error Messages:
- Refer to the user manual for a list of error messages and their meanings.
- Common issues include insufficient blood sample, expired test strips, or incorrect application of the blood sample.
- Inconsistent Readings:
- Ensure hands and the meter are clean.
- Perform a control test to check the meter’s accuracy.
- Verify that test strips are stored correctly and not expired.
By following these steps, you can effectively set up and maintain your FreeStyle Lite blood glucose monitoring system to ensure accurate and reliable blood glucose monitoring.