RESmart Auto Bi-PAP Machine
The RESmart Auto Bi-PAP Machine with RESlex and Heated Humidifier offers many features to increase comfort and provide effective therapy. This is an auto-titrating BiLevel machine that delivers two separate pressures that are adjusted throughout use, one for inhalation and one for exhalation.
Features
Auto Bi-Level Therapy
Heated Humidifier Included
iCode Therapy Data
RESlex Pressure Relief
Auto On/Off
Programmable LCD Display
Auto Bi-level
The RESmart Auto Bi-PAP features auto-adjusting technology that will adjust pressure on each inhalation and exhalation to deliver the optimal pressure needed. When a higher pressure is not needed, the RESmart BPAP 25A will provide a more comfortable, low pressure. The machine can also be set at a fixed inhalation and exhalation pressure if needed.
Heated Humidifier Included
This machine includes the RESmart integrated humidifier which connects directly to the machine without any extra hoses or cables. Heated humidification adds comfort by adding warmth and moisture to the otherwise cool dry air. The humidifier has 5 heat settings along with the option to turn the heat off for use as a passover humidifier.
The RESmart Auto Bi-PAP features RESlex, technology which will lower the pressure slightly on exhalation for a more comfortable therapy. RESlex can be set to one of three levels of relief, and turned off completely if desired.
Auto On/Off
The RESmart Auto Bi-PAP can start or stop therapy when it senses a mask on the user. Auto On is enabled by default and will allow the machine to automatically begin therapy when the user puts on their connected mask and takes a deep breath. Auto Off is disabled by default but when enabled will automatically stop therapy when the user takes the mask off. Both settings can be enabled or disabled as desired.
Programmable LCD Display
The RESmart Auto Bi-PAP features a backlit display to navigate the menu and adjust settings in a dark room. The display can be set to one of three modes: Auto, On, or Off. The “Auto” setting will allow the display to light up when used then will go off after a few seconds. “On” will enable the LCD display to always be lit, while “Off” will leave the display always unlit.
Demonstration Videos
SPECIFICATIONS
This Product Includes…
- RESmart Auto-CPAP Machine
- Heated Humidifier for RESmart Auto-CPAP
- 6 Ft Hose (22mm)
- Carry Case
- Power Cord
- 2 Disposable Filters -1 Installed & 1 Extra
- Manual
Product Specifications
Machine & Humidifier Warranty 2 years
Pressure 4 to 20 cm H2O (.5 increments)
Ramp Time 0 to 60 min. (5-min. increments)
Starting Ramp Pressure 4 to min pressure
Machine Dimensions 8.7″L x 7.6″W x 4.4″D
Machine and Humidifier Dimensions 12.3″L x 7.6″W x 4.4″D
Machine Weight 3 lbs 8.44 oz (1.6 kg)
Machine & Humidifier Weight 5 lbs 4.66 iz (2.4 kg)
Filter Disposable – Dual Filtration
Sound level <30 dBA
Operating Altitude Sea level to 8202 ft
Manual Altitude Settings Can be used in addition to r Auto Altitude Adjustment
- 0 = less than 2460 ft
- 1 = 2460 to 4921 ft
- 2 = 4921 to 8202 ft
Tubing Standard 6 Ft Hose, Flexible plastic, 22mm inner diameter
Device Set-Up Control Panel Push Buttons
Humidification Integrated Heated Humidifier or Pass-over Humidifier
DC Power Use with Inverter
Data Storage Capacity Display: 365 days summary data
Temperature Range for Operation of Machine 41 to 86° F (5-30° C)
Humidifier Temperature Output Settings 1 – 5 (104° to 149° F)
USER MANUAL
FREQUENTLY ASKED QUESTIONS
Helpful Hints
RESmart machines use a standard, 22mm hose and are not compatible with 15mm hoses.
RESlex Setting: The default setting for RESlex is turned off with a setting zero. RESlex is set in the Patient Menu. To access the Patient Menu:
- With the machine turned off, press and hold the Ramp button.
- The “Heater” setting will appear in the window.
- Step through the settings by pushing the “+” button. RESlex is the seventh setting.
- To change the RESlex setting, press the Ramp button one time, on the display screen a square next to the setting number will flash indicating it is active.
- Pressing the “+” and “-” buttons select the desired level of RESlex. 0=Off; 1= the least drop in pressure at the time of exhalation; 3= the most drop in pressure at the time of exhalation.
- Press the Ramp button once to set the RESlex setting.
- Step through the remaining 6 menu items by pressing the “+” button until reaching the word “SAVE”
- Press the Ramp button to LOCK IN any changes made. The screen will display will return to the ready mode.
- NOTE – If the settings are not locked in with SAVE the changes will not be in place when using the machine.
DelayOff with Humidifier Usage: If a humidifier was used during the therapy session, the machine will continue blowing in a ‘DelayOff’ mode at a very low pressure to cool off the heating elements. This is normal operation for the RESmart line of machines. This feature can be changed in the Patient Menu as detailed above for RESlex. Look for the feature “DelayOff.”
When “Enable” is selected, a machine with humidifier will run at a low pressure to cool and dry the machine. When “Disable” is selected, a machine with a humidifier will turn off when the therapy session is ended.
Range for auto-adjusting: The RESmart Auto machine refers the pressure range with the terms MaxAPAP (highest pressure) and Treatment Pressure (lowest pressure). Some manufacturers call these the Max and Min pressures. The machine will adjust to the optimum pressure between the two. When in auto-mode, the pressures displayed on the screen under the word “Ramp” and the ramp time are the starting “Ramp” pressure on the left and the Treatment, or minimum, pressure on the right.
Filter Change: Remove the filter cover by depressing the tab on the bottom of the cover and pulling up on the flare at the bottom of the cover. Insert the filter with the smooth, flat side facing INTO the machine. The textured side of the filter will be showing when installed correctly. Snap the filter cover back in place. Never install a wet filter.
Humidifier Chamber: The humidifier chamber is sealed and cannot be taken apart. It is recommended to fill and empty the chamber through the top port. Alternately, the silicone plug on top of the chamber can be removed to allow emptying. To replace the silicone plug, set the chamber on a hard, even surface, line up the tabs with the holes on the chamber and press firmly downward.
Use with In-Line Bacteria Filter: Please note that an in-line bacteria filter will fit snugly onto the RESmart heated humidifier, but will not make a proper connection to the machine without humidifier. A FlexiTube Angle Adapter for CPAP and BiPAP Machines can be used to connect the in-line bacteria filter to the machine without humidifier.
3B Products Manufacturer Warranty on the RESmart™ Auto CPAP Machine with RESlex with Heated Humidifier: The RESmart™ Auto CPAP Machine with RESlex with Heated Humidifier has a 2 Year Manufacturer Warranty.
CPAP.com will work with the manufacturer on your behalf if the machine needs repairs. Please follow these steps:
- Contact us at cpap@cpap.com or 1-800-356-5221 to receive an RMA (Return Merchandise Authorization) Number before returning the equipment
- Include a note with the machine describing the issue you are experiencing, along with your full contact information to include a return shipping address and the RMA number provided to you
- Ship only the defective items to CPAP.com at 13235 N Promenade Blvd Stafford, TX 77477
- Do not return accessory items such as the carry bag, hose or power cords
- Email updates will be sent to keep you informed as the machine moves through the warranty process
- CPAP.com will contact the manufacturer on your behalf and handle all shipping between us and the manufacturer
- The repaired or replaced unit will be returned to you. Shipping charges may apply.
Please note: The manufacturer warranty is voided by water damage or misuse of the machine.
RELATED ITEMS
Cirrus 5 Concentrator Instructions
Cirrus 5 Concentrator Solution for your respiratory Read more...
RESmart®CPAP – Instructions
RESmart®CPAP The RESmart CPAP Machine with Humidifier Read more...
RESmart® BPAP Auto Bi-level – Instructions
RESmart® BPAP Auto Bi-level The RESmart BPAP 25A Auto Read more...
Luna CPAP – Instructions
Luna CPAP – Instructions The Luna Read more...
RESmart™ Auto-CPAP Instructions
RESmart Auto Bi-PAP Machine The RESmart Auto Read more...
RESmart© Auto CPAP – Instructions
RESmart© Auto CPAP – Instructions Offering advanced Read more...